Setup
-7- Followspot 1200 User Manual Rev. 5
Voltage/Frequency
Selection
The Followspot 1200 uses a single terminal strip to select the operating voltage and
frequency. This operation only requires connecting two wires to a terminal strip, as
indicated below.
Do not connect the fixture to the power outlet without having selected the
voltage and frequency first. Make sure that the circuit’s voltage and frequency
matches your selection to avoid unstable operation or damage to the fixture.
Make sure that there is no power applied to the fixture before op
ening the
fixture’s housing.
Opening the Fixture
1) Unfasten the thumbscrew (T) and slide the front cover (FC) slightly forward.
2) Unscrew the two Allen screws (A) and remove the bracket (B).
3) Carefully pick up and slide the back cover (BC) backward, making sure not to pull
the wires that run from its fans to the Fan Control PCB inside the housing.
Cover Removal
Diagram
Two black wires arrive to the terminal strip (TS). One wire labeled “1” and the other
labeled “2.”
1) Connect the black wires as needed per the table below, without reversing them.
2) Replace the covers.
3) Replace the bracket and secure it with the two Allen screws.
Voltage/Frequency
Terminal Strip
Voltage/Frequency
Selection Table
Voltage/Frequency Wire #1 Wire #2
208 V, 50 Hz Terminal #2 Terminal #4
208 V, 60 Hz Terminal #2 Terminal #3
230 V, 50 Hz Terminal #1 Terminal #6
230 v, 60 Hz Terminal #1 Terminal #5
A
TS
BC
B
FC
T