Chauvet TFX-64CM Work Light User Manual


 
SETUP
Lamp
You will need to install a lamp prior to the initial operation of the fixture. Either three GLC or GKV
575W halogen lamps are included.
Warning! When replacing the lamp, please wait 15 minutes after powering down to allow the
unit to cool down! Always disconnect from main power prior to lamp replacement.
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp
with alcohol and wipe it with a lint free cloth before installation.
LAMP INSTALLATION AND REPLACEMENT
TFX-64CM Lamp Installation
1
2
3
Note: Align labels on lens
cover and fixture to
reinsert.
1) Loosen the thumbscrews as illustrated in figure
1 (3 total) locate
d near the front of the fixture.
2) Pull the lens assembly out from the fixture as
illustr
ated in figure 2.
3) Hold the bi-pin lamps with a napkin and pull
top end of lamp
upwards to remove from
socket as illustrated in figure 3.
4) Hold the new lamp with a lint-free cloth, and
insert lamp do
wnward into the socket as
illustrated in figure 3.
Note: Lens cover can only be inserted one
w
ay! Match up the labels on the lens
cover and the fixture to reinsert the
lens cover properly.
5) Replace lens cover housing and tighten
thumbscr
ews.
6) No lamp alignment is necessary for this fixture.
TFX-64CM User Manual 6 Revision: 2006-11-30/17:23