Page 10 For technical questions, please call 1-800-444-3353. Item 69684
Operating Instructions
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
TOOL SET UP
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Turn the Power Switch of the tool off and unplug the tool from its electrical
outlet before performing any procedure in this section.
TO PREVENT SERIOUS INJURY: DO NOT OPERATE WITH ANY GUARD DISABLED,
DAMAGED, OR REMOVED. Moving guards must move freely and close instantly.
Replacing the Blade
1. Unplug the tool from its power source.
2. Raise the Lower Guard (133) out
of the way and hold it up.
3. Loosen the Guard Pivot Bolt (193) until it
disengages the Guard Pivot Plate (132).
4. Swing the Guard Pivot Plate up and out of the way.
5. Press in the Spindle Lock (150) on the
back of the saw′s head and hold it in.
Spindle
Lock
Figure A
6. Remove the Spindle Bolt* (77) and
Outer Flange (78), see Figure B.
*IMPORTANT: The Spindle Bolt has a left-handed
thread and removes by turning CLOCKWISE.
Note: Make sure the Inner Flange (81)
stays in place on the Spindle.
Figure B
7. Remove the Blade (80) and Arbor Insert (79).
Place the Arbor Insert into a new Blade and
install the new Blade. Make sure that the Blade's
rotation arrow points in the same direction as
the rotation arrow on the Upper Guard (98).
8. Replace the Outer Flange and Spindle Bolt. Position
the cupped side of the Flange against the blade.
Hold in the Spindle Lock (150) and
wrench tighten the Spindle Bolt by turning it
COUNTERCLOCKWISE. Release the Spindle Lock.
9. Rotate the Guard Pivot Plate (132) back into place,
and secure it with the Guard Pivot Bolt (193).
10. WARNING! Make sure the Lower Guard (133)
operates smoothly and properly protects
from the Blade before using the saw.
SAFETY OPERATION MAINTENANCESETUP