Craftsman 919.167551 Air Compressor User Manual


 
17 - ENG

1. Release all air pressure from air
tank. See  in the
Maintenance section.
2. Unplug compressor.
3. Remove shrouds.
4. Remove the outlet pressure gauge
and quick connect from the
regulator.
Outlet
Pressure




5. Remove the regulator.
6. Reapply pipe sealant to outlet
pressure gauge and quick
connect.
7. Assemble quick connect to new
regulator and tighten.
Regulator
Arrow
Quick
Connect
Nipple
8. Apply pipe sealant tape to the
nipple.
9. Assemble the regulator. 
Arrow indicates flow of air. Make
sure it is pointing in the direction
of air flow.
10. Use the hex on quick connect
to tightening regulator. Orient as
shown.
11. Assemble outlet pressure gauge.
Orient outlet pressure gauge to
read correctly.
12. Replace shrouds.

Before you store the air compressor,
make sure you do the following:
1. Review the Maintenance section
on the preceding pages and per-
form scheduled maintenance as
necessary.
2. Drain water from air tank. See 
 under Maintenance.
Water will




3. Protect the electrical cord and
air hose from damage (such as
being stepped on or run over).
Windthemlooselyaroundthe
compressor handle.
4. Store the air compressor in a
clean and dry location.