Dell MD660i Tool Storage User Manual


 
4. In the AMW, select a component in the Hardware pane of the Hardware tab.
5. Select Hardware RAID Controller Module Advanced Run Diagnostics RAID Controller Module.
Controller Failure Conditions
Certain events can cause a RAID controller module to fail and/or shut down. Unrecoverable ECC memory or PCI errors,
or critical physical conditions can cause lockdown. If your RAID storage array is configured for redundant access and
cache mirroring, the surviving controller can normally recover without data loss or shutdown.
Critical Conditions
The storage array generates a critical event if the RAID controller module detects a critical condition that could cause
immediate failure of the array and/or loss of data. The storage array is in a critical condition if one of the following
occurs:
More than one fan has failed
Any midplane temperature sensors in the critical range
Midplane/power supply module failure
Two or more temperature sensors are unreadable
Failure to detect or unable to communicate with peer port
NOTE: If both RAID controller modules fail simultaneously, the enclosure cannot issue critical or noncritical event
alarms for any enclosure component.
Noncritical Conditions
A noncritical condition is an event or status that does not cause immediate failure, but must be corrected to ensure
continued reliability of the storage array. Examples of noncritical events include the following:
One power supply module has failed
One cooling fan module has failed
One RAID controller module in a redundant configuration has failed
A battery has failed or has been removed
A physical disk in a redundant virtual disk has failed
Invalid Storage Array
The RAID controller module is supported only in a Dell-supported storage array. After installation in the storage array,
the controller performs a set of validation checks. The array status LED is lit with a steady amber color while the RAID
controller module completes these initial tests and the controllers are booted successfully. If the RAID controller module
detects a non-Dell supported storage array, the controller does not startup. The RAID controller module does not
generate any events to alert you in the event of an invalid array, but the array status LED is lit with a flashing amber color
to indicate a fault state.
ECC Errors
RAID controller firmware can detect ECC errors and can recover from a single-bit ECC error whether the RAID controller
module is in a redundant or nonredundant configuration. A storage array with redundant controllers can recover from
multi-bit ECC errors as well because the peer RAID controller module can take over, if necessary.
50