Delta A08590 Air Compressor User Manual


 
10- ENG
A08590
Voltage and Circuit Protection
Refer to the specification chart for the voltage and minimum branch circuit
requirements.
Certain air compressors can be operated on a 15 amp circuit if the following
conditions are met.
1. Voltage supply is 108V-132V AC at the outlet.
2. Circuit is not used to supply any other electrical needs (lights, appliances,
etc.).
3. Circuit is equipped with a 15 amp circuit breaker minimum or 15 amp time
delay fuse. NOTE: If compressor is connected to a circuit protected by
fuses, use only time delay fuses marked "D" for Canada and "T" for US.
4. Extension cords comply with specifications.
If any of the above conditions cannot be met, or if operation of the compressor
repeatedly causes interruption of the power, it may be necessary to operate it
from a 20 amp circuit. It is not necessary to change the cord set.
Extension Cords
Using extension cords is not recommended. The use of extension cords will
cause voltage to drop resulting in power loss to the motor and overheating.
Instead of using an extension cord, increase the working reach of the air hose
by attaching another length of hose to its end. Attach additional lengths of
hose as needed.
If an extension cord must be used, be sure it is:
a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot
receptacle that will accept the plug on the product
in good condition
no longer than 50 feet
14 gauge (AWG) or larger. (Wire size increases as gauge number
decreases. 12 AWG, 10 AWG, and 8 AWG may also be used. DO NOT
USE 16 OR 18 AWG.)