Delta Electronics 460V Series Welder User Manual


 
Appendix B Accessories|VFD-S Series
Revision August 2006, SE08, SW V2.61 B-11
460V, 50/60Hz, 3-Phase
Inductance (mH)
kW HP
Fundamental
Amps
Max.
continuous
Amps
3% impedance 5% impedance
0.4 1/2 2 3 20 32
0.75 1 4 6 9 12
1.5 2 4 6 6.5 9
2.2 3 8 12 5 7.5
B.3.2 AC Output Reactor Recommended Value
115V/230V, 50/60Hz, 3-Phase
Inductance (mH)
kW HP
Fundamental
Amps
Max.
continuous
Amps
3% impedance 5% impedance
0.2
1/4 4 4 9 12
0.4
1/2 6 6 6.5 9
0.75
1 8 12 3
5
1.5
2 8 12 1.5
3
2.2
3 12 18 1.25
2.5
460V, 50/60Hz, 3-Phase
Inductance (mH)
kW HP
Fundamental
Amps
Max.
continuous
Amps
3% impedance 5% impedance
0.4 1/2 2 3 20 32
0.75
1
4 6 9 12
1.5
2
4 6 6.5 9
2.2
3
8 12 5 7.5
B.3.3 Applications for AC Reactor
Connected in input circuit
Application 1
Question
When more than one AC motor drive is
connected to the same mains power, and one
of them is ON during operation.
When applying power to one of the AC motor
drive, the charge current of the capacitors
ma
y
cause volta
g
e di
p
. The AC motor drive