DeVilbiss FTV560V Air Compressor User Manual


 
5  ENG
DAMAGE:DAMAGE:
DAMAGE:DAMAGE:
DAMAGE: Each air compressor outfit is carefully tested and
checked before shipment. With improper handling, damage
may result in transit and cause problems in compressor
operation.
Immediately upon arrival, check equipment for both con-
cealed
and visible damages to avoid expenses being incurred to
correct such problems. This should be done regardless of any
visible signs of damage to the shipping container. If this
product was shipped directly to you, report any damages to
carrier and arrange for inspection of goods immediately.
When the tank pressure drops to a certain low level the motor
will restart automatically. The low pressure at which the motor
automatically restarts is called “cut-in pressure.”
Cut-Out Pressure: When you turn on your air compressor
and it begins to run, air pressure in the air tank begins to build.
It builds to a certain high pressure before the motor automati-
cally shuts off - protecting your air tank from pressure higher
than its capacity. The high pressure at which the motor shuts
off is called “cut-out pressure.”
U.L. Listed: Products with the U.L. mark are listed by Under-
writers Laboratories, Inc. (U.L.). Samples of these products
have been evaluated by U.L. and meet the applicable U.L.
standards for safety.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure of
air delivery.
PSIG: Pounds per square inch gauge; a unit of measure of
pressure.
ASME: American Society of Mechanical Engineers; made,
tested, inspected and registered to meet the standards of
ASME.
California Code: Unit may comply with California Code 462
(L) (2)/(M) (2). Specification/model label is on the side of the
tank on units that comply with California Code.
Cut-In Pressure: While the motor is off, air tank pressure
drops as you continue to use your accessory or air tool.
This manufactured air compressor should be operated on not
more than a 50% duty cycle. This means an air compressor
that pumps air more than 50% of one hour
is considered misuse, because the air compressor is under-
sized for the required air demand. Maximum compressor
pumping time per hour is 30 minutes.
You have purchased an air compressor unit consisting of a 2
cylinder, single-stage air compressor pump, an air tank, and
associated controls and instruments.
This air compressor requires no oil. Now you can enjoy all the
benefits of having an air compressor without ever having to
purchase, add or change oil.
Your air compressor can be used for operating paint spray
guns, air tools, caulking guns, grease guns, air brushes,
sandblaster, or inflating tires and plastic toys, spraying weed
killers, insecticides, etc. An air pressure regulator is neces-
sary for most of these applications.
Separate air transformers which combine the functions of air
regulation and/or moisture and dirt removal should be used
where applicable..
Separate air transformers which combine the functions of air
regulation and/or moisture and dirt removal should be used
where applicable.
GLOSSARY
DUTY CYCLE
GENERAL INFORMATION
ON-RECEIPT INSPECTIONON-RECEIPT INSPECTION
ON-RECEIPT INSPECTIONON-RECEIPT INSPECTION
ON-RECEIPT INSPECTION