DeWalt DWFP55130 Air Compressor User Manual


 
English
11
• Circuit is not used to supply any other electrical needs.
• Extension cords comply with specifications.
• Circuit is equipped with a 15 amp circuit breaker or 15 amp
time delay fuse. NOTE: If compressor is connected to a circuit
protected by fuses, use only time delay fuses. Time delay fuses
should be marked “D” in Canada and “T” in the US.
If any of the above conditions cannot be met, or if operation of the
compressor repeatedly causes interruption of the power, it may be
necessary to operate it from a 20 amp circuit. It is not necessary to
change the cord set.
Location
• Locate the air compressor in a clean, dry and well ventilated area.
The air compressor should be located at least 12" (30.5 cm) away
from the wall or other obstructions that will interfere with the flow
of air.
The air compressor pump and shroud are designed to allow for
proper cooling. The ventilation openings on the compressor are
necessary to maintain proper operating temperature. Do not place
rags or other containers on or near these openings.
OPERATION
How to Use Your Unit (Fig. 1)
HOW TO STOP
1. Set the On/Off switch (A) to OFF.
2. Unplug unit when not in use.
BEFORE STARTING
WARNING: Do not operate this unit until you read this instruction
manual for safety, operation and maintenance instructions.
BEFORE EACH START-UP
1. Set the On/Off switch (A) to OFF.
2.
Plug the power cord into the correct branch circuit receptacle.
(Refer to Voltage and Circuit Protection paragraph in the
Installation section of this manual.)
3. Turn the regulator knob (D) counterclockwise to set the outlet
pressure to zero.
4. Attach hose and accessories.
WARNING: Risk of unsafe operation. Firmly grasp air hose
in hand when installing or disconnecting to prevent hose whip.
WARNING: Risk of unsafe operation. Do not use damaged
or worn accessories.
NOTE: The hose or accessory will require a quick connect plug if the
air outlet is equipped with a quick connect body (E).
WARNING: Risk of Bursting. Too much air pressure causes
a hazardous risk of bursting. Check the manufacturer’s maximum
pressure rating for air tools and accessories. The regulator outlet
pressure must never exceed the maximum pressure rating.
NOTICE: Risk of property damage. Compressed air from the unit
may contain wa ter condensation and oil mist. Do not spray un fil tered
air at an item that could be damaged by moisture. Some air tools and
accessories may require filtered air. Read the in struc tions for the air
tools and accessories.
HOW TO START
1. Set the On/Off switch (A) to ON and allow tank pressure to build.
Motor will stop when tank pressure reaches “cut-out” pressure.
2. Turn regulator knob (D) clockwise to increase pressure and stop
when desired pressure is reached.
WARNING: Risk of unsafe operation. If any unusual noise
or vibration is noticed, stop the compressor immediately and
have it checked by a trained service technician.
The compressor is ready for use.