Earlex 3000 Paint Sprayer User Manual


 
NOZZLE & NEEDLE
Unscrew Adjustment Ring (9)
Remove the Air Cap (8)
Completely remove Adjustment Screw (4)
Remove the Spring (3)
Push out the Needle (2) – do not use tools for this
Remove the Fluid Tip (7)
Remove Air Flow Plate (6)
Remove Nozzle Washer (17)
Place all of these items into a container and clean
them using a brush and clean thinners
Clean the inside of the gun
Thoroughly dry these parts before
reassembling
Grease the Fluid Needle Packing (13)
Reassemble parts in reverse order.
It is recommended fitting the fluid tip (7) prior to the
needle
NEVER DISPOSE OF PAINTS OR SOLVENTS INTO
DRAINS. CONTACT YOUR LOCAL
COUNCIL TO ARRANGE COLLECTION OR FOR
DETAILS OF NEAREST REGISTERED DISPOSAL SITE.