Elation Professional 15R Work Light User Manual


 
16
When engaged, this function will allow the lamp to be switched “off” via a DMX
controller. Select “ON” to enable this function or “OFF” to disable it.
Lamp On at Temp.
The fixture is designed to shut the lamp off when an excessive temperature is
sensed inside the head by the on-board CPU. The lamp is shut down to prevent
damage to the lamp and avoids possible internal damage to the head. This function
sets the minimum temperature for lamp restrike after the lamp has been
automatically shut off.
Lamp Off at Temp.
The fixture is designed to shut the lamp off when an excessive temperature is
sensed inside the head by the on-board CPU. The lamp is shut down to prevent
damage to the lamp and avoids possible internal damage to the head. This function
sets the maximum internal operating temperature of the head before the lamp will
automatically be shut down. This function can be set to activate at an internal
temperature between 80° C and 139° C. Inside temperatures below 90° C are not
critical. Temperatures above 90° C should lead to the lamp being switched off.
Please note that the outside temperature should not exceed 45° C.
Personality:
Status setting
Address via DMX - This function allows the DMX address to remotely be
adjusted from a DMX console. This setting requires special settings for both the
controller and the fixture. RDMX is on by default. For operational instructions
please see Section 10/Page 35 of this manual “Remote DMX addressing.”
- - XM542-V1.0-NR