Elation Professional 575H Work Light User Manual


 
Design Par 575H™
©Elation Professional® 45 Design Par 575H™
12. ERROR CODES:
When power is applied, the unit will automatically enter a “reset/test” mode. This mode
brings all the internal motors to a home position. If there is an internal problem with one or
more of the motors an error code will flash in the display in the form of “XXer” were as XX
will represent a function number. For example, when the display shows “03Er,” there is
some type of error with the tilt motor. If there are multiple errors during the start-up process
they will all flash in the display. For example: if the fixtures has errors on channel 1, and
channel 2, at the same time, you will see the error message “01Er”, and “03Er,” flash
repeated 5 times.
If an error does occur during the initial start-up procedure the fixture will self-generate a
second reset signal and attempt to realign all the motors and correct the errors, if the error
persist after a second attempt a third attempt will be made.
If after a third attempt all the errors have not been corrected the fixture will make the
following determinations: 1) 3 or more errors - The fixture cannot function properly with
three or more errors therefore the fixture will place itself in a stand-by mode until
subsequent repairs can be made. 2) Less than 3 errors - The fixture has less than 3 errors,
therefore most other functions will work properly. The fixture will attempt to operate normally
until the errors can be correct by a technician. The errors in question will remain flashing in
the display as a reminder of internal errors.
01Er – PAN movement error:
The yoke is not located in the default position after start-up or after a reset command. This
message will appear after a fixture reset if the pan-yoke’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
03Er – TILT movement error:
The head is not located in the default tilt position after start-up or after a reset command.
This message will appear after a fixture reset if the tilt magnetic-indexing circuit