www.controltechniques.com
18
Specifications and Dimensions
www.controltechniques.com
4.4in
(112mm)
17.6in
(448mm)
6.4in
(162mm)
SP Control
Platform
Weight 3.3lbs
10 min
M
12.7in
(322mm)
9.8in
(249.7mm)
8.9in
(226mm)
2.4in
(62mm)
Size SP0
Weight 4.6lbs
14.5in
(368mm)
3.9in
(100mm)
8.6in
(219mm)
Size SP1
Weight 11lbs
6.1in
(155mm)
14.5in
(368mm)
8.6in
(219mm)
Size SP2
Weight 15.5lbs
9.8in
(250mm)
14.5in
(368mm)
10.2in
(260mm)
Size SP3
Weight 33lbs
12.2in
(310mm)
20.1in
(510mm)
11.7in
(298mm)
Size SP4
Weight 66lbs
11.7in
(298mm)
12.2in
(310mm)
32.3in
(820mm)
Size SP5
Weight 121lbs
11.7in
(298mm)
12.2in
(310mm)
44.5in
(1131mm)
Size SP6
Weight 165.3lbs
Specifications
Dimensions
Environment
Ambient Operating
Temperature
32 to 104 °F (0 to 40 °C)
32 to 122 °F (0 to 50 °C) with derating
Cooling method Forced convection
Humidity 95% maximum non-condensing at 104 °F
(40 °C)
Storage Temperature -40 to 122 °F (-40 to 50 °C)
Altitude 0 to 9,900ft (0 to 3000m). Derate 1% per 328ft
(100m) between 3280ft (1000m) and 9,900ft
(3000m)
Vibration Tested in accordance with IEC 60068-2-6,
2-29, 2-64
Mechanical Shock In accordance with IEC 60068-2-27
Enclosure NEMA 1 (IP 20), NEMA 12 (IP 54) through-panel
mounting
Electromagnetic
Immunity
In compliance with EN 61800-3 and
EN 61000-6-2, and complies with
EN61800-3 2nd environment with built-in lter
Electromagnetic
Emissions
In compliance with EN61000-6-4 when the
recommended RFI lter is used and EMC
installation guidelines are followed
AC Supply
Requirements
Voltage 200 to 240Vac ±10%
380 to 480Vac ±10%
500 to 575Vac ±10%
500 to 690Vac ±10%
Phase 3Ø (SP size Zero: 200 to 240V 1Ø or 3Ø)
Phase Imbalance 2% negative phase sequence (equivalent to 3%
voltage imbalance between phases)
Frequency 48 to 65Hz
Input Power Factor Displacement 0.97
Control
Carrier Frequency 3, 4, 6, 8, 12,16kHz - Panel Mount drives
3, 4, 6kHz - Free Standing and SPM drives
Output Frequency 0 to 3000Hz (Open-loop)
Output Speed 0 to 40,000rpm (Closed-loop)
Frequency Accuracy ±0.01% of full scale
Frequency Resolution 0.001Hz
Analog Input 10 bit + sign (Qty 2); 16 bit + sign (Qty 1)
resolution
Serial
Communications
2-wire RS485
4-wire RS232 or RS485 with SM-APPS module
Protocol is ANSI x 3.28-2.5-A4, or Modbus RTU
Baud rate 300 to 115,200
Braking DC injection braking (stopping and holding) and
dynamic braking transistor standard.
Control Power Ride
Through
Up to 1 second depending on inertia and decel
time
Protection
DC Bus
Undervoltage Trip
175 / 330 / 435Vdc (approximately
124 / 233 / 307Vac line voltage)
DC Bus
Overvoltage Trip
415 / 830 / 990Vdc (approximately 293 / 587 /
700Vac line voltage)
MOV Voltage
Transient Protection
120 Joules, 1500Vdc clamping (line-to-line);
140 Joules, 1815Vdc clamping (line-to-ground)
Drive Overload Trip Current overload value is exceeded
Programmable for Normal Duty or Heavy Duty,
open-loop or closed-loop operation
Instantaneous
Overcurrent Trip
225% of drive rated current
Phase Loss Trip DC bus ripple threshold exceeded
Overtemperature
Trips
Drive heatsink, control board, and option
module(s) monitoring
Short Circuit Trip Protects against output phase to phase fault
Ground Fault Trip Protects against output phase to ground fault
Motor Thermal Trip Electronically protects the motor from