•Feedtheworkpieceinthecorrectdirectionandspeed.Feedthework
pieceintoablade,cutter,orabrasivesurfaceagainstthedirectionofthecuttingtool’sdirection
ofrotationonly.Incorrectlyfeedingtheworkpieceinthesamedirectionmaycausethework
piecetobethrownoutathighspeed.
•Neverleavethetoolrunningunattended,turnthepoweroff.Donot
leavethetooluntilitcomestoacompletestop.
•Neverstartthepowertoolwhenanyrotatingcomponentisin
contact with the work piece.
SERVICE
•
Have Your Power Tool Serviced by a qualified repair person using
only identical replacement parts. Thiswillensurethatthesafetyofthepowertool
ismaintained.
•ServiceYourPowerToolperiodically.Whencleaningatool,becarefulnotto
disassembleanyportionofthetoolsinceinternalwiresmaybemisplacedorpinched.
WARNING:
READ AND UNDERSTAND ALL WARNINGS, CAUTIONS AND OPERATING
INSTRUCTIONS BEFORE USING THIS EQUIPMENT. Failure to follow all
instructions listed below may result in electric shock, fire and/or serious
personal injury.
EXTENSION CORDS
Grounded tools require a three wire extension cord.Doubleinsulatedtoolscan
useeitheratwoorthreewireextensioncord.Asthedistancefromthepowersupplyoutletincreases,
youmustuseaheaviergaugeextensioncord.Usingextensioncordswithinadequatelysizedwire
causesaseriousdropinvoltage,resultinginlossofpowerandpossibletooldamage.Refertothe
tableshownbelowtodeterminetherequiredminimumwiresize.
Thesmallerthegaugenumberofthewire,thegreaterthecapacityofthecord.Forexample:a
14-gaugecordcancarryahighercurrentthana16-gaugecord.Whenusingmorethanoneextension
cordtomakeupthetotallength,besureeachcordcontainsatleasttheminimumwiresizerequired.
Ifyouareusingoneextensioncordformorethanonetool,addthenameplateamperesandusethe
sumtodeterminetherequiredminimumwiresize.
Guidelines for Using Extension Cords
• Ifyouareusinganextensioncordoutdoors,besureitismarkedwiththesufx“W-A”(“W”in
Canada)toindicatethatitisacceptableforoutdooruse.
• Besureyourextensioncordisproperlywiredandingoodelectricalcondition.Alwaysreplacea
damagedextensioncordorhaveitrepairedbyaqualiedpersonbeforeusingit.
• Protectyourextensioncordsfromsharpobjects,excessiveheat,anddamporwetareas.
Recommended Minimum Wire Gauge for Extension Cords (120 Volt)
Nameplate
Amperes
(At Full Load)
Extension Cord Length
25 Feet 50 Feet 75 Feet 100 Feet 150 Feet 200 Feet
0–2.0 18 18 18 18 16 16
2.1–3.4 18 18 18 16 14 14
3.5–5.0 18 18 16 14 12 12
5.1–7.0 18 16 14 12 12 10
7.1–12.0 18 14 12 10 8 8
12.1–16.0 14 12 10 10 8 6
16.1–20.0 12 10 8 8 6 6