Wall Control Operation
Force Control
The force controls are automatically set when the wall control is used
for the rst time with garage door opener. The door MUST complete
one full cycle, from full open to full close and then, full close to full
open, before the settings are automatically recorded.
Contact Reverse Test
NOTE:
The limit and Force settings MUST BE COMPLETED before
performing the Contact Reverse Test.
When the door contacts the board, it should stop and reverse
direction within 2 seconds to the fully open position. Long LED
light on the powerhead will begin to ash RED with the reversal
of the door. Remove the 2" x 4" board after a successful contact
reversal test. The next cycle will clear the ashing red LEDs.
Contact Reverse Adjustment
If the door stops before contacting the board or if it does not
reverse direction to fully open after contact with the board, it
may be due to an improperly set DOWN limit. Verify settings by:
1. Repeat the “Down Travel Limit” section (page 6) to make
certain the door is closing tight against the oor.
2. Repeat the “Force Control” section on the left to set force
limits.
3. Repeat the “Contact Reverse Test” above.
Repeat this process as needed until the door passes the Contact
Reverse Test. For further help, refer to the “Maintenance and
Adjustment” section/Regular Maintenance. (Pages 14-18).
NOTE:
Force controls DO NOT require programming. Force limits are factory
set and rarely require adjustments. Making adjustments to these settings is
covered in the “Maintenance and Adjustments” Section of this Manual (pages
14-18).
FORCE CONTROL IS NOW SET.
12. With the garage door open, lay a 2” x 4” board at on
the oor at the center of the door opening.
11. Press and release the wall console Open/Close button
and allow your garage door to travel and stop at the up
(open) limit.
10. Press and release the wall console Open/Close button
and allow the garage door to travel and stop at the
down (closed) limit.
13. Close the garage door using the Open/Close button on
the wall control.
WARNING
!
TO AVOID INJURY OR DAMAGE
• NEVER adjust the force settings to adjust for damage,
including an unbalanced door, binding door track or
broken spring.
• Perform a CONTACT REVERSE TEST monthly.
AVERTISSEMENT
!
Pour éviter les blessures ou des dommages
• NE JAMAIS régler la force pour compenser des dommages,
y compris une porte mal équilibrée, un rail de porte coinçant
ou des ressorts cassés.
• Tous les mois, EFFECTUEZ LE TEST D’INVERSION AU CONTACT.