Graco 1030 Paint Sprayer User Manual


 
6 309662
Component Description
Compressor Requirements
NOTE: This sprayer requires an external air compres-
sor.
C
A
UTION
Install an air filter on external air compressor to
reduce contamination to spray system.
Air compressor range: 10 scfm to 35 scfm, 30 to 140
psi (0.2--0.97 MPa, 2 to 9.7 bar)
Material
Air Requirements* Minimum
Compressor
Size*
Elastomerics
(textured)
30 scfm at 90 psi
(0.84 m
3
/min at
0.63 MPa, 6.3 bar)
15 HP
Simulated
Accoustical
20 scfm at 60 psi
(0.56 m
3
/min at
0.42 MPa, 4.2 bar)
5.5 HP
Splatter Coat
and
Knockdown
15 scfm at 40 psi
(0.42 m
3
/min at
0.28 MPa, 2.8 bar)
8HP
Orange Peel 20 scfm at 60 psi
(0.56 m
3
/min at
0.42 MPa, 4.2 bar)
8HP
* Material, temperature and volume affect cfm needed
to properly atomize material.
Maintenance
C
A
UTION
D For detailed engine maintenance and specifica-
tions, refer to separate HONDA engine manual.
D Close black fuel shutoff lever whenever you are
transporting sprayer to prevent fuel from flooding
engine.
D Keep sprayer upright and level when operating it
and when transporting it. This prevents crankcase
oil fro m leaking into combustion chamber, which
makes startup very difficult.
Daily: Check engine oil level and fill as needed.
Daily: Check and fill gas tank.
Daily: Check sprayer air filter, clean and replace
element as needed.
After first 20 hours of operation and each 100
hours thereafter: Change oil.
Weekly: Remove engine air filter cover and clean
element. In very dusty environments, check filter daily.
Replace element as needed. Replacement elements
can be purchased from your local HONDA dealer.
Spark plug: Use only a (NGK) BP6ES or BPR6ES
plug. Gap plug to 0.025 to 0.030 in. (0.7 to 0.8 mm).
Always use a spark plug wrench.
6 months: Clean Air Flow Sensor as follows:
1. Fig. 3. Loosen adapter (A). Pull down quick re -
lease (C) and swing out flow sensor regulator.
Disconnect connector (B).
2. Remove inlet fitting (D), retainer ring (E), piston (F)
and spring (G) fro m flow sensor regulator (H).
C
A
UTION
Do not scratch or nick piston (F) or inside of flow
sensor regulator (H).
3. Clean all parts (D, E, F, G). Clean inside of (H)
with a pipe cleaner.
4. Assemble all parts and install flow sensor regula-
tor.
Flow
Sensor Regulator
A
C
ti4366a
Flow
Sensor Regulator
B
D E FG H