Graco 258866. 258863. 3A0159E Paint Sprayer User Manual


 
Setup
10 3A0159E
Setup
Overheating Protection
This sprayer has a built-in protective device to prevent
damage from overheating. The sprayer may automati-
cally shut down after heavy use. If this happens, allow
the sprayer to cool down for 20-30 minutes and resume
spraying.
Installing Suction Tube
Aim the inlet of the suction tube at the front of the mate-
rial cup (towards Spray Tip/Guard Assembly) during
installation.
Spraying Stains or Clear Coats
(Fine-Finish Optimizer)
The Fine-Finish Optimizer must be installed and used
when spraying thin material (similar to water) such as
stain or clear coats. The Fine-Finish Optimizer restricts
the material flow resulting in a finer quality finish.
Installation
1. Remove material cup and suction tube.
2. Remove the cleaning tool before installing the
Fine-finish Optimizer into the sprayer.
3. Push Fine-Finish Optimizer into pump inlet until
completely engaged and re-install suction tube.
Cleanup/Storage
Be sure to remove and clean the Fine-Finish Optimizer
immediately after use. Store the Fine-Finish Optimizer
on the Storage/cleaning Tool supplied to keep the hole
clear of dried material.
Use only water-based or oil-based (mineral
spirit-type) materials with flash point greater than
100° F (38° C). Do not use materials which state
“FLAMMABLE” on the packaging. For more informa-
tion about your material, request MSDS from distribu-
tor or retailer.
Use oil-based material outdoors or in a well-ventilated
indoor area with a flow of fresh air.
Keep spray area well-ventilated. Keep a good supply
of fresh air moving through the area.
NOTICE
Your sprayer is NOT compatible with harsh cleaners
such as chlorine bleach. Using these cleaners will
cause damage to the sprayer.
NOTICE
Failure to install the Fine-Finish Optimizer when using
the NAR311 tip or when spraying thin materials will
cause the motor to overheat and shutdown until it cools.