Graco 310649C Paint Sprayer User Manual


 
Setup
310649C 11
Setup
1. Close fluid valves A and B.
2. Connect A (ISO) and B (RESIN) fluid hoses to fluid
manifold.
3. Engage piston safety lock.
4. Connect the airlines, see Installation page 8.
Attach fluid manifold (D) to gun.
To change position of fluid manifold or use
optional fluid inlets, see Fusion Gun manual
309856 or 309550.
TI2411A
A (ISO)
B (RESIN)
TI2417A
TI3850a
M
TI4764A
5. For Mechanical Purge Guns Only:
a. Open clean off air line valve. Air should
flow from air cap around Ceram Tip (M).
b. Open clean off air valve (K) about 1/4 to
1/2 turn, then adjust air flow as required.
c. Adjust purge rod, see manual 309856.
d. Go to step 10.
For Air Purge Guns Only:
a. Open clean off air line valve. Air should flow from
nozzle (N). Continue through steps below.
6. Disengage piston safety lock.
M
K
TI4765A
N
TI4766A