Operation
8 3A2799A
Flush the Gun
NOTE: This procedure requires a grounded pail of com-
patible flushing fluid.
1. Relieve pressure.
2. Remove the tip guard and spray tip. Soak and clean
the parts.
3. Single component systems only: Remove the pump
intake from the original pail. Put the pump intake in
a grounded pail of compatible solvent.
4. Start the pump at its lowest pressure.
5. Single component systems only: Trigger the gun
into the original pail. When flushing fluid appears,
release the trigger.
6. Two-component systems only: Trigger the gun into a
waste container. When flushing fluid appears
release the trigger.
7. Now trigger the gun into the flushing fluid supply
pail. Circulate the fluid until the system is thoroughly
flushed.
8. After gun is thoroughly flushed, relieve pressure.
To reduce the risk of serious injury, including splashing
fluid in the eyes or on the skin, or static electric dis-
charge when flushing:
• Be sure the entire system, including flushing pails,
is properly grounded.
• Remove the tip guard and spray tip.
• Maintain metal to metal contact between the gun
and the flushing pail.
• Use the lowest possible pressure.
NOTICE
Always flush the pump and gun before the sprayed
fluid cures.
ti19269a