Graco Inc. 1100 Paint Sprayer User Manual


 
14 308415
Technical Data
Category Data
Maximum fluid working pressure 50.0 MPa, 500 bar (7252 psi)
Maximum air input pressure 0.67 MPa, 6.7 bar (97 psi)
Ratio 74:1
Pump performance data See pump manual 308357
Air consumption data See pump manual 308357
Air inlet size 1 in. npsm(f)
Fluid outlet size (at fluid filter) 3/8 npt(m)
Fluid inlet size 2 in. npt(f)
Maximum operating temperature 82_C (180_F)
Wetted parts Pump: See pump manual 308357
Fluid Filter: See manual 307296
Suction Hose, Tube, and Fittings: Polyethylene, Stainless Steel,
Carbon Steel, Nickel and Cadmium Plating
Drain Tube and Fluid Hoses: Nylon
Vitonr is a registered trademark of the DuPont Co.
Sound Pressure Levels (dBa)
(measured at 1 meter from unit)
Input Air Pressures at 15 cycles per minute
Air Motor
0.28 MPa, 2.8 bar
(40 psi)
0.48 MPa, 4.8 bar
(70 psi)
0.63 MPa, 6.3 bar
(90 psi)
0.7 MPa, 7 bar
(100 psi)
Premier 82.5 82.4 83.2 83.0
Sound Power Levels (dBa)
(tested in accordance with ISO 9614–2)
Input Air Pressures at 15 cycles per minute
Air Motor
0.28 MPa, 2.8 bar
(40 psi)
0.48 MPa, 4.8 bar
(70 psi)
0.63 MPa, 6.3 bar
(90 psi)
0.7 MPa, 7 bar
(100 psi)
Premier 90.6 90.6 93.0 95.9