Graco Inc. 289354 Paint Sprayer User Manual


 
Grounding
312473B 9
Grounding
1. Connect the ground wire clamp to a true earth
ground.
2. Ground the object being sprayed, fluid supply con-
tainer, and all other equipment in the spray area.
3. Ground all solvent pails. Use only metal pails. Do
not place on a non-conductive surface such as
paper or cardboard.
Flush
1. Relieve pressure. See Typical Installation, page 7.
2. Remove the air cap. Clean separately.
3. Place the suction tube in solvent.
4. Turn off both air regulators.
5. Open the bleed-type air valve.
6. Open the pump air regulator until the pump starts.
7. When clean solvent flows without air from the gun
stop spraying.
8. Remove the suction tube from the solvent. Continue
to spray until all solvent is out of the gun.
9. Close the bleed type air valve.
10. Relieve pressure. See Typical Installation, page 7.
Read Fire and Explosion Hazard. See page 3.
TI10824A
TI10832A
TI10832A
TI10835A
TI10834A
TI10835A
TI10836A
-
-
TI10827A
+
TI10836A
+
TI10870A
TI10870A
TI10835A
TI10826A
-