Grizzly G1028Z Dust Collector User Manual


 
G1028Z/G1029 Dust Collector -5-
SECTION 2: CIRCUIT REQUIREMENTS
G1028Z Wiring
The G1028Z Dust Collector is pre-wired for 110V,
but can be rewired for 220V. Refer to the wiring
diagram included with this manual for instruction.
Do not attempt to rewire the motor if the diagram
is missing. Contact the appropriate service center
for more information.
A plug is not provided with the G1028Z. It will be
necessary to purchase a standard 110V plug from
your local hardware store. If you are rewiring for
220V, see Figure 1 for the recommended 220V
receptacle.
Circuit Breaker: The 1
1
2 H.P. motor will draw
roughly 18 amps at 110V or 9 amps at 220V. We
recommend a using 20 amp circuit breaker for
110V or 220V operation. Circuit breakers rated
higher will not adequately protect the circuit. If you
are using a fuse, we recommend a 30 amp slow
blow for 110V or 220V operation. Fuses rated
higher will not adequately protect the circuit.