110/220V Operation
SECTION 2: CIRCUIT REQUIREMENTS
Amperage Draw
The Model G0561 features 110/220V motor that
is prewired for 110V and draws the following
amps under maximum load:
Motor Draw at 110V ............................... 16 Amps
Motor Draw at 220V ................................
8 Amps
Circuit Requirements
We recommend connecting this machine to a
dedicated circuit with a verified ground, using the
circuit size given below. Never replace a circuit
breaker with one of higher amperage without con
-
sulting a qualified electrician to ensure compli
-
ance with wiring codes
. If you are unsure about
the wiring codes in your area or you plan to
connect your machine to a shared circuit, you
may create a fire hazard—consult a qualified
electrician to reduce this risk.
110V Circuit ..........................................
20 Amps
220V Circuit ..........................................
15 Amps
Figure 2. 6-15 plug and outlet.
Plug Type
The Model G0561 comes prewired with a NEMA
5-15 plug. If you wish to rewire the motor to 220V
you will need the following 220V plug (see Figure
2 for an example):
220V Plug & Receptacle .............................. 6-15
The Model G0561 can be rewired to operate on a
220V power source. The motor must be rewired
according to the wiring diagram on the motor
label. The wiring configuration can also be found
on the inside of the motor wire cover, as well as
on Page 38.
Wiring for 220V