Grizzly G1030 Dust Collector User Manual


 
-6- G1030 Dust Collector
Figure 1. Recommended 220V receptacle.
Plug/Receptacle: We recommend using the
plug type illustrated in Figure 1. Contact your
local electrical contractor’s supply, a licensed
electrician or our service department if you
have questions about the configuration for
your specific situation. Serious personal
injury may occur.
This equipment must be grounded. Please
ensure that the dust collector is continuously
grounded from the motor to the machine
frame and then to a known ground. Verify that
any existing electrical outlet and circuit you
intend to plug into is actually grounded. If it is
not, it will be necessary to run a separate 12
A.W.G. copper grounding wire from the outlet
to a known ground. Under no circumstances
should the grounding pin from any three-
pronged plug be removed. Serious personal
injury may occur.
We have covered some basic electrical
requirements for the safe operation of your
Dust Collector. These requirements are not
necessarily comprehensive. You must be
sure that your particular electrical configura-
tion complies with local and state codes.
Ensure compliance by checking with your
local municipality or a licensed electrician.
Extension Cords: If used, extension cords
must be rated Hard Service (grade S) or bet-
ter. Conductor size must be 10 A.W.G. for
cords up to 25 feet in length. Your extension
cord must also contain a ground wire and plug
pin. Always repair or replace extension cords
if they become damaged. Serious personal
injury may occur.