Grizzly H8214 Saw User Manual


 
Model H8214 Air Body Saw -5-
Using the Air Body Saw
Always test the blade on a scrap piece of
material similar to the workpiece. Trial and
error is the best way to determine the ideal
cutting speed, feed rate, and depth of cut.
To use the saw:
1. Adjust the support brace for blade
clearance under the workpiece.
2. Attach the
1
/4" NPT male quick connect
fitting to the air inlet plug.
3. Attach the saw to an air supply set at
90 PSI.
4. Hold the saw securely with both hands,
and rest the support brace on the
workpiece.
5. Using the trigger to control RPM, start
the saw, then ease the blade against
the workpiece with a light, but steady,
pressure.
Daily Maintenance
The air body saw MUST have 2-6 drops of
oil directly dropped into the air fitting before
each use. In addition, we recommend using
an in-line filter, lubricator, and regulator, as
shown in Figure 3.
Quick
Connector
Quick
Coupler
Air Hose
Quick
Coupler
Quick
Connector
Lubricator
Filter
Regulator
Air
Compressor
Your
Tool
Figure 3. Installed filter lubricator
regulator.
These procedures should be done after
each use:
Wipe the motor housing and blade with
a dry cloth, or blow off the dust and
debris with compressed air.
Check for damage to tooling, hoses,
housing or other accessories.
Relubricate internal parts with 2-6
drops of oil prior to storage.
To avoid accidental starting,
disconnect the saw from the air
supply when it is not in use.
ACCIDENTAL
START HAZARD!
Disconnect before
service or tool
changes.
AIR PRESSURE
HAZARD!
Never exceed 120
PSI.
LUNG/EAR
INJURY HAZARD!
Wear protective
equipment when
using this tool.
EYE INJURY
HAZARD!
Wear protective
equipment when
using this tool.