Grizzly ZX Saw User Manual


 
-8- G1023Z Series Heavy-Duty 10'' Table Saw
SECTION 3: CIRCUIT REQUIREMENTS
Figure 5. NEMA-style L6-20 plug and outlet.
G1023Z
The motor supplied with the Model Z is a 3 HP
220V single-phase motor. Under normal 220V
use, the motor draws approximately 18 amps.
Use a 20 amp circuit breaker or a 20 amp slow-
blow fuse for 220V operation.
The Model Z does not come with a plug. When
operating at 220V, use a NEMA-style L6-20 plug
and receptacle as shown in Figure 5.
The circuit you use should be dedicated, (i.e., the
machine should provide the only draw from that
circuit). If frequent circuit failures occur when
using this machine, contact our Service
Department or your local electrical contractor.
If the machine is not wired correctly a fire
could result. Make sure your wiring, recep-
tacle, plug, and circuit breaker can handle
the current draw of the machine. If you are
not sure that your electrical circuit can han-
dle the current draw, get a qualified electri-
cian to test your electrical system and do
any required upgrades. DO NOT attempt to
modify an existing circuit by only replacing
the circuit breaker with one rated for a high-
er amperage draw than the wiring, recepta-
cle, and plug are rated for.