Page 9For technical questions, please call 1-800-444-3353.SKU 92857
User-Maintenance Instructions
Procedures not specically explained
in this manual must be performed
only by a qualied technician.
TO PREVENT SERIOUS INJURY FROM
ACCIDENTAL OPERATION:
Detach the air supply and safely discharge any
residual air pressure in the tool before performing
any inspection, maintenance, or cleaning procedures.
TO PREVENT SERIOUS INJURY
FROM TOOL FAILURE:
Do not use damaged equipment.
If abnormal noise, vibration, or leaking air occurs,
have the problem corrected before further use.
TO PREVENT SEROUS INJURY
FROM EXPLOSION:
Lubricate the tool only with
specied lubricants. Lubricate the air inlet
using only pneumatic tool oil. Lubricate the internal
mechanism using only white lithium grease. Other
lubricants may damage the mechanism and may be
highly ammable, causing an explosion.
Cleaning, Maintenance,
and Lubrication
Note: These procedures are in addition to the
regular checks and maintenance explained as part
of the regular operation of the air-operated tool.
1. BEFORE EACH USE, inspect the general condition
of the tool. Check for loose screws, misalignment
or binding of moving parts, clogged Nozzle,
damaged supply hose, cracked or broken parts,
and any other condition that may affect its safe
operation. Do not use damaged equipment.
2. AFTER USE, clean external surfaces of tool with a
clean, most cloth. If necessary, use a mild detergent.
WARNING! Do not use solvents or immerse in
liquids, as damage to Blast Gun may occur.
3. Store in a dry, secure area out of reach of children.
Troubleshooting
Problem Possible Causes Likely Solutions
Tool will not start. 1. Compressor not on.
2. Air line not connected properly.
1. Turn compressor on.
2. Check that air line is connected.
Blast ow surges /
Excessive abrasive
consumption.
Air pressure too low. Increase air pressure.
Clogging and
plugging of
blast ow.
Excessive debris in abrasive. Purge and lter abrasive.
Lack of abrasive
ow.
1. Container empty.
2. Moisture in abrasive
3. Not enough air pressure.
4. Air hose kinked.
5. Excessive debris in abrasive.
1. Fill Container.
2. Use dry abrasive.
3. Increase air pressure.
4. Un-kink air hose.
5. Clean or lter abrasive.
Follow all safety precautions whenever diagnosing or