UNPACKING
When unpacking, check to make sure all the parts shown on the Parts Lists on pages 10,
and 11 are included. If any parts are missing or broken, please call Harbor Freight Tools at
the number shown on the cover of this manual as soon as possible.
OPERATING INSTRUCTIONS
NOTE: For additional references to the parts listed below, refer to the Assembly
Diagrams on pages 10, and 11.
To Check The Oil Level:
1. The Oil Window (20B) is used to determine if oil is needed. The oil level should
always be at the maximum level (red line on the Oil Window). (See Figure A, and
Assy. Diagram B.)
2. WHEN OPENING THE DIP STICK: Make sure to unscrew (do not pull) the Dip
Stick (14B) out. (See Figure A.)
3.
If necessary, add a
premium quality, 30-weight, non-detergent oil
into the Oil Fill
Hole until the level of oil reaches the maximum level as indicated on the Oil Window
(20B). The optimal capacity of the oil reservoir is 30 ounces.
Do not overfill. Then
thread the Dip Stick back into the Oil Fill Hole, being careful not to strip the plastic
threads.
FIGURE A
Dip Stick (14B)
Oil Window (20B)
Front Cover (18B)
To Turn The Air Compressor On:
1. Check to make sure the Water Drain Valve (10A) is fully closed.
(See Assy. Diagram A.)