To Turn The Air Compressor On:
Fully close the Water Drain Valve (10A). 1. (See Assy. Diagram A.)
Pull on the Pressure Relief Valve (5A) briey to ensure that it does not stick.2.
Turn the Air Flow Valve (6A) to its “OFF” position.3.
Connect the air hose (not provided) to the Air Flow Valve (6A) of the Air Compres-4.
sor. Then, connect the other end of the air hose to the pneumatic tool (not pro-
vided) that is to be used.
5. To extend the life of your air tools and equipment, it is recommended to install
an oiler and water lter in series (available from Harbor Freight Tools) with the Air
Output Line of the Air Compressor.
Note: Plug the Power Cord of the Air Compressor into a 230 V~ electrical source.
Pull 6. up on the “ON/OFF” Power Switch (1A) to turn the Air Compressor on.
(Push down on the “ON/OFF” Power Switch to turn the Air Compressor off.)
Allow sufcient time for the Tank Pressure Gauge (4A) to indicate 7. 80 PSI before
using the Air Compressor.
Turn the Air Flow Valve (6A) to its “ON” position to allow air to the pneumatic tool.8.
With the Air Compressor turned on, the operation is automatic and under the con-9.
trol of the automatic switches inside the box under the Power Switch (1A).
NEVER open the power switch box or adjust the controls within.
To Adjust The Air Output To The Pneumatic Tool:
Note: When adjusting the air pressure being forwarded to the pneumatic tool, you will
need to compare the pressure readings of both the Tank Pressure Gauge (3A) and
the Tool Pressure Gauge (4A). The reading on the Tank Pressure Gauge dictates
the maximum/minimum air pressure at which the Tool Pressure Gauge may also
be set.
With the Air Compressor running, and the air hose and pneumatic tool hooked up 1.
to the Air Compressor, pull up on the Tool Pressure Adjuster (2A). Turn the Tool