Wiring Diagram 1
(Standard)
Wiring Diagram 2
OPTIONAL WIRING
is fixture is provided with a sensor rated for 360 Watts. Since the fixture is only rated 100 Watts, 260 Watts of additional
lighting may be controlled by this sensor.
When determining what a fixture is rated for, do not simply look at the rating on the lamp in the fixture. Look at the
marking which specifies the maximum lamp wattage for which the fixture is suitable.
Once you have selected the fixtures to be connected and determined their maximum ratings, add these ratings up.
For instance, if you have 3 fixtures rated 100 Watts, 150 Watts, and 75 Watts respectively, you have a total load of 325
Watts.
Wiring Diagram 1 – When wiring to control a standard light xture: Strip the motion sensor’s red wire and con-
nect to the standard light’s black wire. Connect all white wires together. Total fixture ratings must not exceed 360 Watts
(3.0 A).
Wiring Diagram 2 – When wiring to control another motion sensing light xture (Master / Slave): Strip the
red wire in both light fixtures. Connect the red wire of the controlling (master) fixture to the red and black wires of the
controlled (slave) fixture. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A).
Wiring Diagram 3 – When wiring so either motion light turns on the both motion lights (Master / Master):
Strip the red wire in both light fixtures. Connect the red wire of one fixture to the red wire of the second fixture. Note:
In most installations, an additional wire (same gage as existing house wire) will have to be installed in the house to
connect the two fixtures as master / master. Connect all white wires together and all black wires together. Total fixture
ratings must not exceed 360 Watts (3.0 A).
Master
Wiring Diagram 3
Black
White
Red
Green or
Bare
Slave
Black
White
Red
Green or
Bare
Master
Black
White
Red
Green or
Bare
Master