Heath Zenith 5630 Work Light User Manual


 
2
598-1132-06
INSTALLATION
For easy installation, select an existing wall mounted
light fixture with a wall switch for replacement.
For best performance, mount the fixture between 6 and
8 feet (2.4 m) above the ground.
Note: Mounting fixture higher than 8 ft. (2.4 m) will
reduce coverage distance.
1. Remove the existing light fixture.
2. Remove two cover
screws and remove
cover.
Screws
3. Remove the reflector
screw and remove
reflector.
Screw
Cover
Reflector
4. Mount adapter bracket. Note: The adapter bracket
is universal. Rotate or flip over bracket as needed
to align with junction box holes.
IF JUNCTION BOX MOUNTING HOLES ARE
HORIZONTAL:
a. Align slots on bracket with mounting holes in
junction box.
b. Apply silicone caulk around junction box or on
adapter bracket.
c. Press adapter bracket against junction box. Verify
junction box mounting holes align with slots. Wait
5 minutes. Go to step 5.
Caulk
Junction Box
Mounting Adapter
Bracket
Mounting Slots
Horizontal
Mounting Holes
DualBrite
®
FEATURE
With the DualBrite
®
control in the up
position, the light will come on at low
level from dusk to dawn. If motion is
detected in the Normal mode, the light
will turn on to full brightness.
*When switching Normal modes, wait
about 1
1
/
2
minutes for the circuitry to
calibrate.
Move ON-TIME Switch to
1, 5, or 20 minutes
MODE SWITCHING SUMMARY
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the Normal mode.
DUSK
TO
DAWN
(DIM)
NORMAL
WARNING: Turn power off at circuit breaker
or fuse.