Heath Zenith 5630 Work Light User Manual


 
4
598-1132-06
SET LIGHT CONTROLS
1. Select desired ON-TIME for the light to stay on after
motion is detected (1, 5, or 20 minutes).
2. Set DualBrite
®
control to Dusk-to-Dawn (DIM) or
Normal.
Note: Meets the ENERGY STAR
®
guidelines when
DualBrite
®
function is off and ON-TIME is 1 or 5
minutes.
3. Reinstall cover.
4. Turn power on at the fuse or circuit breaker and
light switch.
SPECIFICATIONS
Range ........................................ Up to 30 ft. (9,1 m). [varies with surrounding temperature]
Sensing Angle ........................... Up to 190°
Electrical Load ........................... Up to 100 Watt Maximum Halogen, 78 mm T-type
Power Requirements ................. 120 VAC, 60 Hz
Operating Modes ....................... TEST, NORMAL, and MANUAL MODE
Time Delay ................................ 1, 5, 20 minutes from last motion sensed
DualBrite
®
Feature .................... Dusk-to-Dawn
SYMPTOM
Light will not come
on.
Light comes on
in daylight.
Light comes on for
no apparent rea-
son.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Halogen lamp is loose or
burned out.
3. Fuse is blown or circuit breaker
is turned off.
4. Daylight turn-off is in effect (re-
check after dark).
5. Incorrect circuit wiring, if this is
a new installation.
1. Wall light may be installed in a
relatively dark location.
2.
Wall light is in Test. (Set control
switch to an ON-TIME position).
1. Light control may be sensing small
animals or automobile traffic.
2. DualBrite
®
Timer is on.
SYMPTOM
Light turns
off too late in
Dusk-to-Dawn
setting.
Light stays on
continuously.
Light flashes
on and off.
POSSIBLE CAUSE
1. Wall light may be installed in a relatively
dark location.
1. Wall light is located too close to nearby
objects that cause heat to trigger the
sensor such as an air vent, dryer vent,
or brightly-painted, heat-reflective
surface.
2. Wall light is in DualBrite
®
mode.
3. Light control is in Manual mode (Switch
to Normal).
1. Heat being reflected from other objects
may be affecting the sensor. (Move or
cover other objects to find which ones
are causing the problem).
2. Wall light is in the Test mode. Return
to the 1, 5, or 20 minute timer mode.
TROUBLESHOOTING GUIDE
30 ft.
(9 m)
8 ft.
(2.4 m)
190°
Maximum Range Maximum
Coverage Angle
Motion
Motion
Least Sensitive Most Sensitive
Sensor
The detector is less sensitive to motion directly towards it.