Heath Zenith 598-1283-00 Work Light User Manual


 
2
598-1283-00
INSTALLATION
1. Remove
two nuts.
For best performance, mount the fixture
about 6 feet (1.8 m) above the ground.
2. Remove
Mounting Plate.
5. Attach mounting
plate to junction box.
Wire Path
3. Tighten screws
finger tight.
MAX
SENS
MIN
4. Set sensitivity con-
trol on back of fixture
to mid-position.
Ground Screw
ON-TIME Switch at 1,
5, or 10 minutes
Mode Switching Summary
Flip light switch
off for one sec-
ond then back
on*
* If you get confused while switching modes, turn
the power off for 1
1
/
2
minutes, then back on.
After the calibration time the control will be in
the AUTO mode.
MANUAL MODE
AUTO
TEST
DualBrite
®
Two-Level Lighting
Light comes on at a reduced light level
(accent) for selected time after dusk (Off, 3
hr., 6 hr., until dawn). If motion is sensed, the
light turns on full bright for the ON-TIME (1,
5, or 10 minutes) then returns to the accent
light level.
Bulb Saver Technology
When motion is detected, bulb saver brightens
bulb in under 2 seconds. This technology
increases bulb life (up to four times) and
provides a warmer welcome for guests. The
bulb saver feature works with or without
the DualBrite
®
feature activated. The bulb
saver feature works automatically - no user
adjustment is required.
WARNING: Turn power off at circuit
breaker or fuse.