Heath Zenith SH-5412 Work Light User Manual


 
4
598-1158-04
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
Loosentheclampscrewinthe
sensor ball joint and gently
rotatethesensor.
Walk through the coverage
area noting where you are
whenthelightsturnon(also,
theLEDwillashseveraltimes
whenmotionisdetected).Move
thesensorheadup,down,or
sidewaystochangethecover-
agearea.Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
AdjusttheRANGEasneeded.
RANGE set too high may
increasefalsetriggering.
Secure the sensor head by
tightening the clamp screw.
Donotovertightenthescrew.
SettheamountofTIMEyouwantthelightstostay
onaftermotionisdetected(1,5,or10minutes).
SPECIFICATIONS
Range............Upto70ft.(21m)[varieswith
surroundingtemperature].
SensingAngle......Upto180°
ElectricalLoad......Upto240WattMaximumTung-
sten[Upto120Wattmaximum
eachlampholder.]
PowerRequirements.120VAC,60Hz
OperatingModes....TEST, AUTO and MANUAL
MODE
TimeDelay ........1,5,10minutes
Range............Adjustable
HeathCoLLCreservestherighttodiscontinueprod-
uctsandtochangespecicationsatanytimewithout
incurringanyobligationtoincorporatenewfeatures
inproductspreviouslysold.
NOTE: Sensor has a 1
1
/
2
minutewarm up period
beforeitwilldetectmotion.Whenrstturned
on,wait1
1
/
2
minutes.
Bottom of Sensor
Avoid aiming the control at:
•Objects thatchange temperature rapidly,such as
heating vents and air conditioners.These heat
sourcescouldcausefalsetriggering.
•Areaswherepets or trafficmaytriggerthecontrol.
•Nearby large, light-colored objectsreectinglight
maytriggertheshut-offfeature.Donotpointother
lightsatthesensor.
70ft.
(21m)
8ft.
(2.4m)
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Least Sensitive Most Sensitive
WARNING: Risk of fire. Do not aim the lamps
at a combustible surface within 3 ft. (1 m).
Maximum Range Maximum
Coverage Angle
RANGE
1051TEST
ON-TIME
MAXMIN
RANGEON-TIME
10 5 1 TEST
MINUTES
MIN MAX
NOTE:MeetstheENERGYSTAR
®
guidelineswhenused
with120WMaxbulbs.
TurntheRANGEcontroltothemidposition(halfway
betweenMINandMAX)andtheON-TIMEcontrol
totheTESTposition.
Motion
Motion
180°
Sensor
NOTE:
Ifxtureismountedhigherthan8ft.(2.4m),aiming
thesensordownwillreducecoveragedistance.
Thedetectorislesssensitivetomotiondirectlytowardsit.