3
598-1161-03
Remove the existing light fixture.
❒ Install mounting strap to junction box using screws
appropriate for your junction box.
The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
Thread all fixture wires through the large holes in
the gasket as shown.
Connect the junction box wires to the light fixture
wires as shown. Twist together and secure with wire
connectors.
Bulb Installation
❒ When relamping, turn power off and let the fixture
cool.
❒ Remove glass cover and remove the old bulb by
pushing the bulb towards the socket indicated on
the metal reflector.
❒ To insert the new bulb, follow the instructions printed
on the metal reflector.
❒ Check that the bulb is seated properly.
❒ Reinstall the glass cover.
White to White
Black to Black
Connect any fixture ground wire(s) and the cover plate
ground screw to the junction box ground wire.
Gasket
Mounting Strap
Mounting
Bolt
Mount the Light Control
Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
Push the rubber plug firmly into place.
If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone weather
sealant.
Rubber
Plug
WARNING: Turn power off at circuit breaker
or fuse.
Wire the Light Control