Heath Zenith SH-9250-WH Work Light User Manual


 
-8-
598-1341-00
Finish Mounting
Align the cover plate, gasket, and the mounting
bracket hole. Secure with M5 x 0.8 x 40 mm
mounting screw supplied.
Push the rubber plug firmly into place.
If not installed on a weatherproof box, caulk
between the cover plate and mounting sur-
face with silicone weather sealant.
Adjust the lamp holders by loosening the
thumb screws but do not rotate the lamp hold
-
ers more than 180° from the factory setting.
When screwing in the floodlamps, do not
overtighten.
To avoid water damage and
electrical shock, keep lamp
holders aimed below horizontal.
Specifications
Range . . . . . . . . . . . . . . . 70 feet (21.0 m); 100 feet
(30.5 m) with Range Boost.
Varies with surrounding
temperature.
Sensing Angle
. . . . . . . . . Up to 270° (Adjustable)
Fixture Load
. . . . . . . . . . Up to 300 Watts Maximum
Tungsten
Incandescent [Up
to 150 Watts maximum each
lamp holder.]
Sensor Load Capacity
. . . Up to 1000 Watts (8.3 amps)
Maximum
Tungsten
Incan-
descent
Power Requirements
. . . . 120 VAC, 60 Hz
Operating Modes
. . . . . . . TEST, AUTO, and MANUAL
OVERRIDE
Time Delay
. . . . . . . . . . . 1, 5, 20 minutes
HeathCo LLC reserves the right to discontinue
products and to change specifications at any time
without incurring any obligation to incorporate new
features in products previously sold.
Rubber Plug