Replacing carbon brushes:
(For parts name, refer to Fig. 1)
Loosen the set screw then remove the cap cover. Remove the brush cap and carbon
brush. After replacing the carbon brush, do not forget to tighten the brush cap securely
and to install the cap cover.
5. How to replace grease
This machine is full air-tight construction to protect against dust and to prevent lubricant
leakage. Therefore, the machine can be used without lubrication for long periods.
Replace the grease as described below.
Grease replacement period
After purchase, replace grease after every 6 months of usage. Ask for grease replacement
at the nearest HITACHI Authorized Service Center. Proceed for replacement of grease.
Grease replenishment
CAUTION:
Before replenishing the grease, turn the power off and pull out the power plug.
(1) Remove the crank cover and wipe off the
grease inside. (Fig. 18)
(2) Apply 0.7 oz (20 g) of HITACHI Electric Hammer
Grease A (standard accessory, contained in
tube) to the crank case.
As the tube contains 1 oz (30 g) of grease,
supply 2/3 of the contained grease.
(3) After replenishing the grease, install the crank
cover securely.
NOTE: The HITACHI Electric Hammer Grease
A is of the lower viscosity type. When
the supplied grease tube is consumed,
purchase from a HITACHI Authorized
Service Center.
6. Service and repairs
All quality power tools will eventually require servicing or replacement of parts because
of wear from normal use. To assure that only authorized replacement parts will be
used, all service and repairs must be performed by a HITACHI AUTHORIZED SERVICE
CENTER, ONLY.
7. Service parts list
A: Item No.
B: Code No.
C: No. Used
D: Remarks
Fig. 18
Crank cover