Hitachi L300P Series Welding System User Manual


 
2- 6
2.5 Return to an initialization setup (Factory-shipment state)
The rewritten setting value is initialized and it can return to the state at the time of factory shipments.
The career of a trip is clearable.
The contents of initialization are as follows.
RUN time and power supply ON time are unclearable.
Item FNC mode Data Contents
00 Only a trip career is cleared.
01
Only initialization of setting value is carried out.
Setting value will be in the state at the time of
factory shipments.
Initialization
selection
b084
02 A clearance of a trip career and a setup are
initialized.
00
Initial cofiguration value for inside of Japan
01 Initial cofiguration value for Europe
Initial data
selection
b085
02 Initial cofiguration value for USA
(The initialization method)
Please initialize by the following methods after setting up the above and a setting item.
HITACHI HITACH HITACHI
(1) Where a function key, a
rise key, and a down key
are pushed simultaneously,
please push stop/reset key.
If a display blinks, please
detach a stop/reset.
Then, please detach a
function key, a rise key, and
a down key.
(2) Under initialization
The above-mentioned
display is for the inside
of Japan. Others are as
follows.
(3)When displayed on a
monitor part as "d001",
it is the completion of
initialization.
A display turns around a left end.
Under initialization for Europe
Under trip career initialization
Under initialization for USA