Hitachi Koki USA n 5024a Staple Gun User Manual


 
13
English
THE OPTIONAL SEQUENTIAL TRIP MECHANISM (SINGLE
SHOT PARTS) is for use where precision fastener
placement is desired and must be operated in accordance
with the following Method of Operation.
You must first depress the push lever (upward
position) where you want to drive a staple and then
pull the trigger. After the each staple is driven,
completely release the trigger and lift the tool off the
work surface. An OPTIONAL SEQUENTIAL TRIP
MECHANISM may reduce the possibility of bodily
injury to you or others in the work area. This is
because it is less likely to drive an unwanted staple if
you keep the trigger pulled and accidentally bump the
push lever against yourself or others. An OPTIONAL
SEQUENTIAL TRIP MECHANISM may also reduce the
speed of operation compared to the standard contact
trip mechanism.
NOTE:
Both STANDARD CONTACT TRIP MECHANISM and
OPTIONAL SEQUENTIAL TRIP MECHANISM are safe if
used as described above and accroding to all
warnings and instructions.
Always handle staples and package carefully. If
staples are dropped, collating bond may be broken.
After stapling:
1) disconnect air hose from the Stapler;
2) remove all staples from the Stapler;
3) supply 5 10 drops of Hitachi pneumatic tool
lubricant into the air plug on the Stapler; and
4) open the petcock on the air compressor tank to
drain any moisture.
ADJUSTING THE STAPLING
DEPTH
To assure that each staple penetrates to the same depth,
be sure that:
1) the air pressure to the Stapler remains constant
(regulator is installed and working properly), and
2) the Stapler is always held firmly against the
workpiece.
If staples are driven too deep or shallow into the
workpiece, adjust the stapling in the following order.
1 DISCONNECT AIR HOSE FROM STAPLER.
2 If staples are driven too deep, turn the adjuster to the
shallow side.
Adjustments are in half-turn increments.
3 If staples are driven too shallow, turn the adjuster to
the deep side.
Stop turning the adjuster when a suitable position is
reached for a stapling test.
4 Connect the air hose.
ALWAYS WEAR SAFETY GLASSES.
Perform a stapling test.
5 DISCONNECT AIR HOSE FROM STAPLER.
6 Choose a suitable position for the adjuster.
2
Too Deep
3
Too Shallow
Turn Adjuster
Flush
Turn Adjuster
Flush
Disconnect
air hose
15
Adjuster