Hobart Welding Products 120 Welder User Manual


 
OM-210 088 Page 16
3-7. Electrical Service Guide For 230 VAC Model
Input Voltage
230
Input Amperes At Rated Output
19.5
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
30
Min Input Conductor Size In AWG/Kcmil
14
Max Recommended Input Conductor Length In Feet (Meters)
66 (20)
Min Grounding Conductor Size In AWG/Kcmil
14
Reference: 1996 National Electrical Code (NEC) S-0092-J
3-8. Installing Wire Spool And Adjusting Hub Tension
S-0499
15/16 in
Standard Wire Spool (8 in)
1 Lb Wire Spool (4 in)
Turn wingnut. When a slight force is
needed to turn spool, tension is set.
Tools Needed:
Adjusting Hub Tension
Install spool so welding wire feeds from bottom.