OM-4418 Page 17
5-2. Grounding Generator When Supplying Building Systems
GND/PE
1 2
2
3
800 576-B
! Ground generator to sys-
tem earth ground if supply-
ing power to a premises
(home, shop, farm) wiring
system.
1 Equipment Grounding
Terminal
2 Grounding Cable
Use #10 AWG or larger insulated
copper wire.
3 Ground Device
. Use ground device as stated
in electrical codes.
Open/On
1
Closed/Off
5
-3. Engine Prestart Checks
803 468-D
Full
Gasoline
1/2 in
(13 mm)
Check all fluids daily. Engine must
be cold and on a level surface. Unit
is shipped with 10W30 engine oil.
Engine stops if oil level gets too low.
1 Fuel Valve
Open valve.
. Close fuel valve before moving
unit or carburetor may flood
and make starting difficult.
Fuel
Add fresh fuel before starting
engine the first time . Fill fuel tank up
to 1/2 in. (13 mm) from top to allow
room for expansion. Check fuel lev-
el on a cold engine before use each
day.
Oil
After fueling, check oil with unit on
level surface. If oil reservoir is not
full, add oil until oil nearly overflows
at oil fill.
. This unit has a low oil level
shutdown switch to prevent
starting an engine that is low on
oil. However, some conditions
may cause engine damage be-
fore the engine shuts down.
Check oil level often and do not
use the low oil level shutdown
system to monitor oil level.
. To improve cold weather start-
ing, use correct grade oil for
cold weather (see engine own-
er’s manual).
. Always close fuel valve after
stopping unit. Moving unit
with fuel valve open may
cause carburetor flooding
and make starting difficult.