Hobart Welding Products 210 597J Welding System User Manual


 
OM-4418 Page 18
5-4. Connecting To Weld Output Terminals
803 469-D / 226 005 / 803 778-A
1 AC Weld Output Terminals
Connect work and electrode cable
s
to weld terminals. (Polarity does no
t
matter for AC welding.)
! Failure to properly connec
t
weld cables may cause ex
-
cessive heat and start a fire
,
or damage your machine.
2 Weld Output Terminal
3 Supplied Weld Output
Terminal Nut
4 Weld Cable Terminal
5 Copper Bar
Remove supplied nut from weld
output terminal. Slide weld cable
terminal onto weld output termina
l
and secure with nut so that weld
cable terminal is tight against cop
-
per bar. Do not place anything be
-
tween weld cable terminal and
copper bar. Make sure that the
surfaces of the weld cable termi
-
nal and copper bar are clean.
Tools Needed:
3/4 in
1
5
3
4
Do not place
anything between
Correct Installation
Incorrect Installation
2
weld cable terminal
and copper bar.