3-7. Volt-Ampere Curves
The volt-ampere curve shows the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
rsb13.1 12/94 ST-184 477-A / ST-184 475-A / ST-184 480-A
A. CC/DC (Standard)
B. CC/AC (Models with Optional Polarity/AC Selector Switch)
C. CV/DC (Models with Optional CV-3 Module)
0
20
40
60
80
100
0 100 200 300 400 500 600 700
AC Amperes
AC Volts
0
20
40
60
80
100
0 100 200 300
400
500 600 700
DC Amperes
DC Volts
Ranges: 190Max
110270
85210
55110
Min65