3-3. Fuel Consumption
210 593
3-4. Duty Cycle
212 950
Duty cycle is the percentage of 10
minutes that unit can weld at rated
load without overheating.
Y Exceeding duty cycle can
damage unit and void
warranty.
Continuous Welding
100% Duty Cycle at 90 Amperes CC/AC
3 Minutes Welding 7 Minutes Resting
30% Duty Cycle at 140 Amperes CC/AC