Husky HDN10500 Nail Gun User Manual


 
6
Operating Instructions
www.chpower.com
6
Operating Instructions
USER-MAINTENANCE
INSTRUCTIONS (Continued)
ASSEMBLY PROCEDURE FOR SEALS
When repairing a tool, the internal
parts must be cleaned and lubricated.
Parker O-lube or equivalent must be
used on all o-rings. Each o-ring must be
coated with O-lube before assembling.
A small amount of oil must be used on
all moving surfaces and pivots. After
reassembling, a few drops of 30W
non-detergent oil or equivalent, must
be added through the air line before
testing.
STORAGE
The tool should be stored in a cool dry
place.
Interchange Information
Can use 1/2 inch to 1 inch pins from the
following branded 23 g micropinners:
Senco FP10, Air Locker P630, Porter
Cable PIN100, Grex P635, and Max
NF235A.
Notes