Husqvarna FS 800 E Cordless Saw User Manual


 
9. Technical specifications
The table below gives the technical specifications for the
FS800 E/EM floor saw. It is extremely important that you
check these before:
- Choosing a floor saw.
- Choosing and fitting a diamond blade.
- Connecting to the mains supply.
- Choosing a power cable.
- Choosing the cutting depth.
- Transporting the machine.
If you are unsure about the meaning of the technical specifica-
tions or ordering spare parts, please contact your supplier
FS800 E/EM ART. NOS. 50020 AND 50030
Motor rating kw 7.5
Voltage and type of supply V/phase/Hz 400/3/50 or
220/3/50
Power cable REVE 5x2.5
Polarity Europa plug 16 Amp.
Phase inverter in socket
Drive shaft speed rpm 1150
Max. peripheral speed. m/s 63
Max. diamond blade diameter mm 800
Parking brake yes
Base plate optional
accessory
Chain drive optional
accessory
Max. Cutting depth mm 320
Length approx. mm 1500
Width approx. mm 780
Height approx. mm 1120
Weight (excl. blade) approx. kg 220
Noise noise power <101.7
Lw rel. pw
according to ISO
744 dB(A)
Noise noise pressure <84.8
Lp rel. 0µPa at
ear during
operation B(A)
Vibration according to. 0.8 m/s2 (H/A)
ISO 7505
10
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
FAULT CAUSE REMEDY
Blade turns wrong way. Phases from power cable are inverted. Change polarity using phase inverter.
Drive belt is slipping. Belt is too slack. Adjust belt tension.
Drive belt is worn. Replace the drive belt.
Drive belt is oily. Clean the drive belt.
Motor cuts out. Cutting depth too large. Reduce cutting depth.
Cutting speed too high. Advance more slowly.
Diamond segments are worn. Replace diamond blade.
Electrical fault. Contact a qualified electrician.
No cooling water. Nozzles are blocked. Clean nozzles.
Water pressure low.
Blade gets jammed. Blade is worn. Replace blade.
Cut closing up. Cut smaller sections, or
support from below using props or a jack.
Motor does not start. Electrical fault. Contact your electrician.
Emergency stop activated. Determine cause. When fault is
fixed, pull up emergency stop.