Impulse hammer drill Drill User Manual


 
[ 10 ]
Cleaning the Vision Eye
Remove the Vision Eye ball detent (See page 6 for Vision Eye Assembly). Gently pull back
the Vision Eye cover and remove the Vision Eye screw. Remove the Vision Eye from the
Vision Eye slot and wipe with a clean paper towel or q-tip.
NOTE: The ball detent for the Vision Eye is longer than the standard ball detent on the
opposite side.
General Body Cleaning
The Impulse body and outer surface items can be cleaned with a water/alcohol mix applied to
a rag or cloth. Do not immerse the Impulse in any liquid.
Troubleshooting
The following section will review troubleshooting procedures for the Impulse.
Gun will not fire
- Verify correct air pressure from regulator.
- Check firing mode with Eye-On Mode and Eye-Off Mode. (See page 4 for setting
the firing mode)
- Verify that battery is charged and is an alkaline battery.
- Verify that the bolt pin is correctly inserted through the bolt and into the bolt actuator.
- Verify that bolt is inserted correctly, with the air input facing down.
- Reset dwell to zero and readjust to desired velocity. (See page 5 for resetting the Impulse
Operating Pressures)
- Verify that solenoid is correctly plugged into the circuit board.
- Verify that trigger is contacting the firing switch. (Set the firing mode to Eye-Off Mode
and verify that the LED blinks when the trigger is pulled.)
Air leaking out breech (barrel)
- Verify the bolt is in the open position. The bolt pin should be at the back of the groove
it cycles in.
- Clean valve. (See page 9 for instructions on cleaning the valve.)
Internal Air Leak
- Clean and lightly lubricate Spool valve with Dow 33 lubricant.
- Check o-rings on hammer assembly (See Hammer Assembly diagram on page 6)
- Change solenoid gasket.