Installation and Lubrication
Size air supply line to ensure tool’s maximum operating pressure (PMAX) at tool inlet. Drain
condensate from valve(s) at low point(s) of piping, air lter and compressor tank daily. Install a
properly sized Safety Air Fuse upstream of hose and use an anti-whip device across any hose
coupling without internal shut-o, to prevent hose whipping if a hose fails or coupling
disconnects. See drawing 46807384 and table on page 2. Maintenance frequency is shown in
circular arrow and dened as h=hours, d=days, and m=months of actual use. Items identied as:
1. Air lter 7. Coupling
2. Regulator 8. Safety Air Fuse
3. Lubricator 9. Oil
4. Emergency shut-o valve 10. Grease - during assembly
5. Hose diameter 11. Grease - through tting
6. Thread size
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.