SET-UP PROCEDURE WITH OPTIONAL
M104
HYDRAULIC CHECK
13
Assemble hydraulic check to mounting bracket and assemble
mounting bracket to tool using washers (Y14-8) and cap screws
Measure distance from tap point to work piece - distance “Y”.
Distance “X” between hydraulic check plunger and trip bracket
must be less than distance “Y” to prevent damage to tap point
when it approaches the work piece.
Loosen the cap screws (Y154-48) and position hydraulic check
to obtain correct setting for distance “X”.
Tighten cap screws (Y154-48) securely before operating unit,
Increase the air flow thru the Feed Control Valve marked “F” by
opening two (2) full turns from closed position, This will allow tap
to advance rapidly until the trip bracket contacts plunger of hydraul-
ic check.
l
The Hydraulic Feed Rate Adjustment is located at the nameplate
end of the Hydraulic Check. Rotate extended spindle until the slot
on the spindle is located midway between the highest and the
lowest settings.
l
Start tap unit and the tap will advance at a rapid rate until the
trip bracket contacts plunger of hydraulic check,
l
Slowly rotate the Hydraulic Feed Rate counterclockwise for faster
feed rate or clockwise for slower feed rate.
Y
ADJUSTMENT SCREW
BASIC REMOTE CONTROL FOR START
AND EMERGENCY RETRACT FUNCTIONS
3-WAY PALM BUTTON VALVE MODEL
461-3 WITH GUARD 20975 (RECESSED
GREEN BUTTON). INSTANT TUBE CONNECTIONS
AND SPRING RETURN
“OUT” PORT
3-WAY PALM BUTTON VALVE (MODEL 461-2).
RED BUTTON WITHOUT GUARD. INSTANT TUBE
CONNECTIONS AND SPRING RETURN
. PACKAGED 10 TO A BOX
REMOTE OPERATION
Remote operation of the unit may be achieved by connecting a 3-way valve to the remote start and/or remote retract ports, as shown above.
TO START - depress the remote button momentarily. The unit will advance the drill to a preset depth and automatically retract to the initial position whereupon the unit will stop.
EMERGENCY RETRACT - depress the emergency button momentarily. This signal to the unit will shift the built-in pressure operated valve, commanding the unit to retract immediately
to the initial position whereupon the unit will stop.
NOTE: MANUAL START and EMERGENCY RETRACT buttons on the tool are fully operational even when remote control is used, The manually operated buttons can be used when
set-up IS required.
Shown below is the some system in schematic form.