Leica 763495 Laser Level User Manual


 
9
Appendix
Leica DISTO™ D2 762202b gb
D
GB
F
I
E
P
NL
CN
Switching off the beep
Press and hold simultaneously for 5
seconds:
The beep is switched off.
To reactivate it, press and hold for 5 seconds.
Appendix
Display Notices
All display notices are either displayed with or
"Error". The following errors can be corrected.
Technical Specifications
Cause Correction
204
Calculation error Repeat procedure
252
Temperature too
high
Let device cool down.
253
Temperature too
low
Warm device up
255
Received signal too
weak, time for a
measurement too
long.
Use a target plate
256
Received signal too
strong
Use target plate (gray
side)
257
Faulty measure-
ment, too much
background light
Use target plate (brown
side)
258
Outside of the range
of measurement
Select measurement
distance within the
range of measurement
Error Cause Correction
Error Hardware error Should this message
remain active after
switching the instru-
ment off and on several
times, please contact
the dealerhip.
Range 0.05 m to 60 m*
Measuring accuracy (2
σ
)
typically ± 1.5 mm**
Smallest unit displayed 1 mm
Laser class 2
Laser type 635 nm, < 1 mW
Protection against
splashes and dust
IP 54, dust-proof,
splash-proof
Autom. power off:
Laser
Instrument
after 60 s
after 180 s
Illumination
9
Folding out endpiece
9
Battery life,
Type 2 x AAA
up to
5 000 measurements
Dimension 111 x 43 x 23 mm
Weight 90 g
Cause Correction